36 research outputs found

    Advanced quantum techniques for future gravitational-wave detectors

    Get PDF
    Quantum fluctuation of light limits the sensitivity of advanced laser interferometric gravitational-wave detectors. It is one of the principal obstacles on the way towards the next-generation gravitational-wave observatories. The envisioned significant improvement of the detector sensitivity requires using quantum non-demolition measurement and back-action evasion techniques, which allow us to circumvent the sensitivity limit imposed by the Heisenberg uncertainty principle. In our previous review article (Danilishin and Khalili in Living Rev Relativ 15:5, 2012), we laid down the basic principles of quantum measurement theory and provided the framework for analysing the quantum noise of interferometers. The scope of this paper is to review novel techniques for quantum noise suppression proposed in the recent years and put them in the same framework. Our delineation of interferometry schemes and topologies is intended as an aid in the process of selecting the design for the next-generation gravitational-wave observatories. © 2019, The Author(s)

    Double optical spring enhancement for gravitational-wave detectors

    Get PDF
    Currently planned second-generation gravitational-wave laser interferometers such as Advanced LIGO exploit the extensively investigated signal-recycling technique. Candidate Advanced LIGO configurations are usually designed to have two resonances within the detection band, around which the sensitivity is enhanced: a stable optical resonance and an unstable optomechanical resonance—which is upshifted from the pendulum frequency due to the so-called optical-spring effect. As an alternative to a feedback control system, we propose an all-optical stabilization scheme, in which a second optical spring is employed, and the test mass is trapped by a stable ponderomotive potential well induced by two carrier light fields whose detunings have opposite signs. The double optical spring also brings additional flexibility in reshaping the noise spectral density and optimizing toward specific gravitational-wave sources. The presented scheme can be extended easily to a multi-optical-spring system that allows further optimization

    A new type of quantum speed meter interferometer: measuring speed to search for intermediate mass black holes

    Get PDF
    The recent discovery of gravitational waves (GW) by LIGO has impressively launched the novel field of gravitational astronomy and it allowed us to glimpse at exciting objects we could so far only speculate about. Further sensitivity improvements at the low frequency end of the detection band of future GW observatories rely on quantum non-demolition (QND) methods to suppress fundamental quantum fluctuations of the light fields used to readout the GW signal. Here we invent a novel concept of how to turn a conventional Michelson interferometer into a QND speed meter interferometer with coherently suppressed quantum back-action noise by using two orthogonal polarisations of light and an optical circulator to couple them. We carry out a detailed analysis of how imperfections and optical loss influence the achievable sensitivity and find that the configuration proposed here would significantly enhance the low frequency sensitivity and increase the observable event rate of binary black hole coalescences in the range of 102−103M⊙10^2-10^3 M_\odot by a factor of up to ∼300\sim300.Comment: 8 pages, 5 figures. Modified figures and text in v

    Comparison of different sloshing speedmeters

    Get PDF
    By numerical simulation, we compare the performance of four speedmeter interferometer configurations with potential application in future gravitational wave detectors. In the absence of optical loss, all four configurations can be adjusted to yield the same sensitivity in a fair comparison. Once we introduce a degree of practicality in the form of lossy optics and mode mismatch, however, the situation changes: the sloshing Sagnac and the speedmeter of Purdue and Chen have almost identical performance showing smaller degradation from the ideal than the speedmeter of Freise and the speedmeter of Miao. In a further step, we show that there is a similar hierarchy in the degree of improvement obtained through the application of 10 dB squeezing to the lossy speedmeters. In this case, the sensitivity of each speedmeter improves, but it is greatest for the sloshing Sagnac and the speedmeter of Purdue and Chen, in particular in the lower part of the target frequency range

    Narrowing the filter cavity bandwidth via optomechanical interaction

    Full text link
    We propose using optomechanical interaction to narrow the bandwidth of filter cavities for achieving frequency-dependent squeezing in advanced gravitational-wave detectors, inspired by the idea of optomechanically induced transparency. This not only allows us to achieve narrow bandwidth, comparable to the detection band of few hundred Hz, with tabletop optical cavities, but also to tune the bandwidth over a wide range, which is ideal for optimizing sensitivity for different gravitational-wave sources. The experimental challenge for its implementation is the stringent requirement on low thermal noise, which would need superb mechanical quality factor that is quite difficult to achieve by using currently-available low-loss mechanical oscillators; one possible solution is to use optical dilution of the mechanical damping, which can considerably relax the requirement on the mechanics.Comment: 5 pages + 3 appendix. 4 figures and 2 tables Accepted by Physical Review Letter

    Interferometer readout-noise below the Standard Quantum Limit of a membrane

    Get PDF
    Here we report on the realization of a Michelson-Sagnac interferometer whose purpose is the precise characterization of the motion of membranes showing significant light transmission. Our interferometer has a readout noise spectral density (imprecision) of 3E-16 m/sqrt(Hz) at frequencies around the fundamental resonance of a SiN_x membrane at about 100 kHz, without using optical cavities. The readout noise demonstrated is more than 16 dB below the peak value of the membrane's standard quantum limit (SQL). This reduction is significantly higher than those of previous works with nano-wires [Teufel et al., Nature Nano. 4, 820 (2009); Anetsberger et al., Nature Phys. 5, 909 (2009)]. We discuss the meaning of the SQL for force measurements and its relation to the readout performance and conclude that neither our nor previous experiments achieved a total noise spectral density as low as the SQL

    Local-Oscillator Noise Coupling in Balanced Homodyne Readout for Advanced Gravitational Wave Detectors

    Get PDF
    The second generation of interferometric gravitational wave detectors are quickly approaching their design sensitivity. For the first time these detectors will become limited by quantum back-action noise. Several back-action evasion techniques have been proposed to further increase the detector sensitivity. Since most proposals rely on a flexible readout of the full amplitude- and phase-quadrature space of the output light field, balanced homodyne detection is generally expected to replace the currently used DC readout. Up to now, little investigation has been undertaken into how balanced homodyne detection can be successfully transferred from its ubiquitous application in table-top quantum optics experiments to large-scale interferometers with suspended optics. Here we derive implementation requirements with respect to local oscillator noise couplings and highlight potential issues with the example of the Glasgow Sagnac Speed Meter experiment, as well as for a future upgrade to the Advanced LIGO detectors.Comment: 7 pages, 5 figure

    Achieving ground state and enhancing entanglement by recovering information

    Get PDF
    For cavity-assisted optomechanical cooling experiments, it has been shown in the literature that the cavity bandwidth needs to be smaller than the mechanical frequency in order to achieve the quantum ground state of the mechanical oscillator, which is the so-called resolved-sideband or good-cavity limit. We provide a new but physically equivalent insight into the origin of such a limit: that is information loss due to a finite cavity bandwidth. With an optimal feedback control to recover those information, we can surpass the resolved-sideband limit and achieve the quantum ground state. Interestingly, recovering those information can also significantly enhance the optomechanical entanglement. Especially when the environmental temperature is high, the entanglement will either exist or vanish critically depending on whether information is recovered or not, which is a vivid example of a quantum eraser.Comment: 9 figures, 18 page
    corecore